China Glass Factory · Technical answers

How is the U-value of an insulating glass unit calculated, and what value should a hot-climate project specify?

The U-value of an IGU is the centre-of-glass value calculated to EN 673 or ISO 10292; add the frame and spacer effect with EN ISO 10077-1 for the whole window. In hot climates a double-glazed Low-E unit reaches 1.1–1.4 W/m²K.

Three things drive the number: the cavity gas, the number of Low-E coatings, and the cavity width. A 6 mm + 12 mm air + 6 mm clear unit is about 2.7 W/m²K. Replacing air with argon gives about 2.6. Adding one Low-E coating on surface 3 takes it to about 1.6. A double-silver coating with argon and a warm-edge spacer reaches about 1.1.

For Gulf and Southeast Asian projects the useful target is a whole-window U of 1.8–2.2 W/m²K together with a solar heat gain coefficient (SHGC) below 0.30. Chasing U below 1.1 in a cooling-dominated climate buys almost nothing, because the cooling load is driven by solar gain, not by conduction.

Which numbers decide the U-value of an IGU?

Calculation standardEN 673 / ISO 10292
Window assemblyEN ISO 10077-1
6 + 12 air + 6 clear≈ 2.7 W/m²K
6 + 12 argon + 6, one Low-E≈ 1.6 W/m²K
6 + 12 argon + 6, double silver Low-E, warm edge≈ 1.1 W/m²K
Recommended for hot climatesU 1.8–2.2 W/m²K whole window, SHGC < 0.30

Where do U-value comparisons go wrong?

Related: Insulating glass units Low-E glass Company fact sheet
Need a quote against your drawing?

Send the glass schedule, thickness build-up and destination port to info@cnglassworks.com or on WhatsApp (reply within 1 hour) / phone +86 138 3303 3053. A specification review and reference price come back within one working day.

Figures verified by the factory on 2026-11-02. Sizes are manufacturing limits, not project guarantees.

Price from USD ___ per sqm FOB Qinzhou, depending on thickness, coating and quantity.

Last updated: 2026-11-22